Dissolved Oxygen Meters
- (7)
- (1)
- (13)
- (9)
- (7)
- (1)
- (1)
- (2)
- (4)
- (1)
- (1)
- (8)
- (2)
- (1)
- (2)
- (2)
- (5)
- (1)
- (4)
- (7)
- (1)
- (9)
- (1)
- (6)
- (5)
- (2)
- (11)
- (13)
- (6)
- (5)
- (2)
- (1)
- (3)
- (3)
- (2)
- (10)
- (5)
- (1)
Filtered Search Results
Bellco Glass, Inc. Single CellTrol,pH/DO/Temp 4 Pumps
The CellTrol II can be configured to accept a variety of analog probe signals from a cell culture vessel. Standard signals include pH, dissolved oxygen, temperature, weight, redox, and tachometer feedback from the agitator. A digital input signal from a level probe can be used for anti-foam addition for level control. The CellTrol II control module monitors bioreactor process valves and performs PLC ( Allen-Bradley Programmable Logic Controller) based process control. A touch screen operator interface provides access to all based PLC control functions and allows viewing and modification of control parameters. PLC control drives the inc/dec outlets assigned to each channel as well as to pumps mounted on the front of the unit. The pump assignments are user defined from the operator interface. Cell-SoftSoftware are also available, optional tethered speed drive, optional single support flow station and weight platforms are sold separately.. MADE IN THE USA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. Single CellTrol,pH/DO/Temp 2 Pumps
The CellTrol II can be configured to accept a variety of analog probe signals from a cell culture vessel. Standard signals include pH, dissolved oxygen, temperature, weight, redox, and tachometer feedback from the agitator. A digital input signal from a level probe can be used for anti-foam addition for level control. The CellTrol II control module monitors bioreactor process valves and performs PLC ( Allen-Bradley Programmable Logic Controller) based process control. A touch screen operator interface provides access to all based PLC control functions and allows viewing and modification of control parameters. PLC control drives the inc/dec outlets assigned to each channel as well as to pumps mounted on the front of the unit. The pump assignments are user defined from the operator interface. Cell-SoftSoftware are also available, optional tethered speed drive, optional single support flow station and weight platforms are sold separately.. MADE IN THE USA
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
COLE PARMER 3P EE DO 2000 BT METER W STAND
502538075 EE DO 2000 BT METER W STAND
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. DO Membrane Kit,12mm
Membrane replacement kit for:7803-315307803-315407803-315507803-31560
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. T-96 Membrane Kit,12mm DO Mettler
T-96 membrane replacement kit for:7803-315357803-315457803-315557803-30565
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bioanalytical Systems Inc INOTIV INC
NC4030617 GALVANIC ISOLATION
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Biospherix ProOx C21 O2/CO2 Controller & 3-Shelf C-Chamber (Incubator SubChamber)
ProOx C21 O2/CO2 Controller & 3-Shelf C-Chamber (Incubator SubChamber)
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Ohiolumex Co Inc Optical Oxygen Meter
Optical Oxygen Meter
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. DO Tester Cable, 12 in
Do Tester Cable, 12"
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Bellco Glass, Inc. DO Membrane Kit, 12mm Broadley-James
KA1204 Cartridge Kit for 12 mm DO Sensors (4 pieces)This kit contains everything required to replace four membrane cartridges on a 12 mm OxyProbe. Everything is conveniently packaged in one box for easy storage.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Fisherbrand™ Traceable™ Portable Dissolved Oxygen Meter
Traceable™ Portable Dissolved Oxygen Meter is traceable to NIST™ standards.
| Accuracy (DO) | 0 to 20mg/L, ±0.3mg/L or 2% of reading, whichever is greater, 20 to 50mg/L, ±6% of reading |
|---|---|
| Warranty | 3 Years |
| Width (English) | 4.75 in. |
| Length (Metric) | 23 cm |
| Length (English) | 9 in. |
| Saturation Range | 0 to 500% Air Saturation |
| Sensor Types | Thermistor |
| For Use With (Application) | DO, Temperature |
| Width (Metric) | 12 cm |
| Battery Type | C Alkaline |
| Includes | Meter, DO/temperature probe, 4 C Batteries, Cable |
| Battery Life | 2000 hr. |
| IP Rating | IP-67 |
| Temperature (English) Range | 23°F to 113°F |
| Resolution (DO) | 0.01, 0.1mg/L |
| Weight (English) | 2 lb. |
| Certifications/Compliance | CE, IP67 |
| Resolution (Temperature) | 0.1°C |
| Saturation Resolution | 0.1% Air Saturation |
| Accuracy (Temperature) | ±0.3°C |
| Dimensions (L x W) | 9 x 4.75 in. (23 x 12 cm) |
| Range (DO) | 0 to 50mg/L |
| Height (English) | 2.5 in. |
| Weight (Metric) | 0.91 kg |
Fisherbrand™ Traceable™ Portable Dissolved Oxygen Meter Pens
Compact, rugged design with large, easy-to-read digits. Fisherbrand Traceable Portable Dissolved Oxygen Meter Pen has a water-resistant design with O-ring seal and membrane keypad which assures a long life in severe lab or harsh plant environments.
Fisherbrand™ accumet™ Research AR40 Benchtop Dissolved Oxygen Meter Kit
Easy-to-use dissolved oxygen meter provides accuracy, reliability and intuitive operation.
Thermo Scientific™ Orion Star™ A213 Dissolved Oxygen Benchtop Meter
Reliably measure dissolved oxygen (RDO optical/polarographic) and temperature with this benchtop meter for advanced lab analysis.
| Temperature (Metric) Range | 0.0°C to 50.0°C |
|---|---|
| Resolution (Polarographic DO) | 0.01, 0.1mg/L |
| Pressure Range | 400 to 850 mmHg |
| Memory | Non-volatile memory preserves data log, calibration log and meter settings |
| Languages | English,Spanish,French,Italian,German,Chinese,Portuguese and Korean available with software update |
| Measurement Modes | Dissolved Oxygen (% Saturation),Dissolved Oxygen (mg/L with Temperature and Barometric Pressure) |
| Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) |
| Barometric Pressure Correction | 400 to 850mmHg, automatic using built-in barometer or manual entry |
| Battery Life | 800 hours |
| Data Management Details | Transfer single, range or all data points to printer or computer |
| Display Type | Graphic LCD with Backlight |
| Data Points | 2000 with Date and Time Stamp |
| Calibration Modes | Water-saturated air, air-saturated water, manual (Winkler titration), zero point |
| Certifications/Compliance | CE, TUV 3-1, FCC Class A |
| Temperature Probe Calibration | 1 point temperature offset calibration |
| Salinity Factor | 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity |
| Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
| Warranty | 3 Year Meter Warranty |
| Sensor Types | RDO optical dissolved oxygen sensor or polarographic dissolved oxygen sensor |
| Percent Saturation Range Polarographic DO | 0.0 to 600.0 % saturation |
| Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m |
| Battery Type | Four AA (sold separately) |
| Relative Humidity Range | 5 to 85 %, non-condensing |
| Range (RDO) | 0.00 to 50.00 mg/L |
| Dimensions (L x W x H) | 24 cm x 18 cm x 11 cm (9.5 in. x 7.1 in. x 4.3 in.) |
| Percent Saturation Range (RDO) | 0.0 to 500.0 % saturation |
| Temperature Selection | Automatic with ATC temperature probe |
| Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys |
| Outputs | USB, RS232 |
| Backlight Option | Yes (Selectable) |
| Percent Saturation Relative Accuracy (RDO) | ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation |
| Range (Polarographic DO) | 0.00 to 90.00 mg/L |
| Accuracy (Barometer) | ±6mmHg |
| Methods | 10 per channel with password protection |
| Pressure Resolution | 1 mmHg |
| Channels | 1 |
| Resolution (RDO) | 0.01, 0.1mg/L |
| Percent Saturation Resolution (RDO) | 0.1, 1 % saturation |
| Percent Saturation Relative Accuracy (Polarographic DO) | ±2 % saturation or ±2% of reading whichever is greater |
| Inputs | 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe) |
| Accuracy (Temperature) | ±0.1°C |
| Weight (Metric) | 0.9 kg |
| Temperature (English) Operating | 41°F to 113°F (ambient) |
| Accuracy (Polarographic DO) | ±0.2mg/L or ±2% of reading, whichever is greater |
| AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
| Alarm Output | High/low limit alarm, calibration due alarm |
| IP Rating | IP54 |
| Percent Saturation Resolution (Polarographic DO) | 0.1, 1 % saturation |
| Model | Orion Star A213 RDO Optical/Dissolved Oxygen/Temperature Benchtop Meter |
| Weight (English) | 2 lb. |
| Resolution (Temperature) | 0.1°C (0.1°F) |
| Temperature (Metric) Operating | 5°C to 45°C (ambient) |
| Percent Saturation Range (Polarographic DO) | 0.0 to 600.0 % saturation |
| Accuracy (RDO) | ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L |